Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention
JAMA Network Open · 30.06.2026 · 9 (6) · e2620871
DOI: 10.1001/jamanetworkopen.2026.20871 ↗Kurz gefasst
Randomisierte kontrollierte Studie in der Zeitschrift JAMA Network Open, online erschienen am 30.06.2026. Verfasst von Felice E E van Veen und 19 weiteren Autor:innen. Beteiligte Einrichtung: Department of Urology, Erasmus University Medical Center, Rotterdam, the Netherlands. Hauptthemen laut MEDLINE: Urinary Retention, Urinary Tract Infections, Equipment Reuse, Urinary Catheters. Die Arbeit nennt 26 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Importance Clean intermittent catheterization (CIC) is the preferred management for urinary retention. Single-use catheters generate substantial environmental and financial burdens, whereas evidence on the safety of reusable catheters is limited.
Objective
To examine whether reusable catheters are noninferior to single-use catheters for CIC with respect to urinary tract infection (UTI) incidence. Design, Setting, and Participants This multicenter, noninferiority randomized clinical trial was conducted between February 21, 2020, and April 3, 2025, at 12 Dutch hospitals and included patients aged 16 years or older performing CIC at least twice daily, with 1-year follow-up.
Interventions
Participants were randomly assigned to reusable or single-use catheters. Reusable catheters were disinfected daily in 2% sodium hypochlorite solution, rinsed before and after use, and replaced every 2 weeks; single-use catheters were permitted for 20% or less of weekly catheterizations in the reusable group. Main Outcomes and Measures The primary outcome was UTI incidence per patient-month. Secondary outcomes included catheter-related complications, adverse events, and patient-reported outcomes. The noninferiority margin was set at an absolute difference of 0.07 UTIs per patient-month.
Results
A total of 386 patients (mean [SD] age, 61.4 [15.9] years; 243 [63%] male; and 139 [36%] with neurogenic lower urinary tract dysfunction) were included. In the reusable catheter group, 72 of 185 participants (39.0%) discontinued study participation, mainly due to reduced ease of use and urethral irritation. In the modified intention-to-treat population (n = 326), mean (SD) follow-up was 12.0 (1.9) months in the single-use group and 11.4 (2.9) months in the reusable group. During this period, 1 or more UTIs occurred in 59 of 191 single-use catheter users (30.9%) and 40 of 134 reusable catheter users (29.9%). The incidence rate was 0.054 (95% CI, 0.040-0.069) vs 0.050 (95% CI, 0.035-0.067) UTIs per patient-month, with an absolute difference of −0.004 (95% CI, −0.025 to 0.019), meeting the predefined noninferiority margin. Catheter-related complications and serious adverse events were comparable between groups, whereas low-grade adverse events, mainly urethral irritation, were more frequent in the reusable group (37 [20.0%] vs 9 [4.7%]). Catheter-related quality of life was higher with reusable catheters, whereas catheterization satisfaction was higher with single-use catheters; overall health-related quality of life did not differ between groups. Conclusions and Relevance In this randomized clinical trial of patients with urinary retention, reusable catheters were noninferior to single-use catheters for UTIs, with variable tolerability and patient-reported outcomes highlighting the importance of individual preference and the need for design enhancements to improve usability and broaden implementation. Trial Registration National Trial Register: NL8296
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Autor:innen und Institutionen
- Department of Urology, Erasmus University Medical Center, Rotterdam, the Netherlands.
- Department of Urology, Zuyderland Medical Center, Heerlen, the Netherlands.
- Department of Urology, Rijnstate, Arnhem, the Netherlands.
- Department of Urology, Isala, Zwolle, the Netherlands.
- Department of Urology, Canisius-Wilhelmina Hospital, Nijmegen, the Netherlands.
- Department of Urology, Amphia Hospital, Breda, the Netherlands.
Zitieren
APA
van Veen, F. E. E., Christiaans, C. H. H., Berendsen, S. A., van Doorn, T., Boekhorst, J. L., Koedood, S., Kuenen, M., Roelofs, A. W. T. M., Witte, L. P. W., Dijkstra, S., van Brakel, J., van der Wielen, G. J., Roelofs, L. A. J., Wolterbeek, J. H., Koldewijn, E. L., van Asten, J., Bleumer, I., Hansen, B. E., Scheepe, J. R., & Blok, B. F. M. (2026). Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention. JAMA Network Open, 9(6), e2620871. https://doi.org/10.1001/jamanetworkopen.2026.20871
Vancouver
van Veen FEE, Christiaans CHH, Berendsen SA, van Doorn T, Boekhorst JL, Koedood S, et al. Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention. JAMA Network Open. 2026;9(6):e2620871. doi:10.1001/jamanetworkopen.2026.20871
BibTeX
@article{vanVeen2026,
author = {van Veen, Felice E E and Christiaans, Coen H H and Berendsen, Sophie A and van Doorn, Tess and Boekhorst, Jessica L and Koedood, Selma and Kuenen, Maartje and Roelofs, Anita W T M and Witte, Lambertus P W and Dijkstra, Siebren and van Brakel, Jos and van der Wielen, Gerard J and Roelofs, Luc A J and Wolterbeek, Josien H and Koldewijn, Evert L and van Asten, Joost and Bleumer, Ivar and Hansen, Bettina E and Scheepe, Jeroen R and Blok, Bertil F M},
title = {Single-Use vs Reusable Catheters for Intermittent Catheterization in Patients With Urinary Retention},
journal = {JAMA Network Open},
year = {2026},
volume = {9},
number = {6},
pages = {e2620871},
doi = {10.1001/jamanetworkopen.2026.20871}
}
EUVIMED