EUVIMEDEUVIMED entdecken
Multizentrische StudieValidierungsstudieOpen Access

Multicenter Prospective Validation of an Updated Proprietary Sepsis Prediction Model

Multizentrische prospektive Validierung eines aktualisierten proprietären Sepsis-Vorhersagemodells

Andrew Wong, Danielle Currey, Megan Schwinne, Brenna Park-Egan, Sean Meyer, Andrew Gutting, Jie Cao, Sharaf Khan, Raymund Dantes, Tony Pan, Timothy Buchman, Karandeep Singh und 4 weitere

JAMA Network Open · 27.02.2026 · 9 (2) · e260181

DOI: 10.1001/jamanetworkopen.2026.0181 ↗

Auf einen Blick

In 4 US-Gesundheitssystemen zeigte das aktualisierte Epic Sepsis Model v2 eine gute Diskrimination, aber starke standortabhängige Unterschiede sowie niedrige positive Vorhersagewerte.

Fragestellung

Wie gut validiert das ESM v2 bei stationären Erwachsenen die Sepsisvorhersage im Vergleich zu ESM v1 und zur klinischen Sepsiserkennung?

Methode

Prognostische Studie mit multizentrischer prospektiver Validierung an 4 US-Gesundheitssystemen; Vergleich mit ESM v1 und klinischer Sepsiserkennung.

Ergebnisse

Bei 227 091 stationären Episoden erfüllten 7401 (3,3 %) die Sepsis-Kriterien. AUROC auf Fall-Ebene 0,82 bis 0,92; auf Vorhersage-Ebene bei 12 Stunden 0,75 bis 0,85. Gegen klinische Erkennung 0,80 bis 0,90; PPV 0,13 bis 0,26.

Einschränkungen

Hohe institutionelle Variabilität, niedriger positiver Vorhersagewert und hohe Alarmbelastung.

Schlussfolgerung der Autor:innen

Die multizentrische prospektive Validierung in 4 großen US-Gesundheitssystemen zeigte eine verbesserte Diskrimination für die frühe Sepsisvorhersage, aber hohe standortabhängige Unterschiede, niedrige PPV und hohe Alarmbelastung.

Kernaussagen

  • ESM v2: AUROC auf Fall-Ebene 0,82 bis 0,92
  • PPV blieb niedrig: 0,13 bis 0,26
  • Hohe institutionelle Variabilität und hohe Alarmbelastung

Deutsche Zusammenfassung: KI-gestützt aus dem Original-Abstract erstellt; alle Zahlen wurden automatisch mit dem Original abgeglichen. Maßgeblich ist der Original-Abstract.

Kurz gefasst

Multizentrische Studie in der Zeitschrift JAMA Network Open, online erschienen am 27.02.2026. Verfasst von Andrew Wong und 15 weiteren Autor:innen. Beteiligte Einrichtung: University of Michigan Medical School, Ann Arbor. Hauptthemen laut MEDLINE: Prediction Algorithms, Sepsis. Die Arbeit wurde bisher 25-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NCI NIH HHS, NHLBI NIH HHS.

Auf einen BlickAbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance The Epic Sepsis Model version 2 (ESM v2) is a widely implemented proprietary sepsis prediction model, but no multicenter, external validation of its performance has been reported to guide adoption and use.

Objective

To conduct a multicenter validation of the ESM v2 to compare performance against the original ESM v1, outline differences across heterogenous clinical sites, and compare model performance against clinician recognition of sepsis. Design, Setting, and Participants This prognostic study included adult inpatient encounters at 4 large US health systems between August 31, 2023, and March 11, 2025. At each site, data were collected for a consecutive period immediately following new model implementation. Data were analyzed from July 23 to August 19, 2025. Main Outcomes and Measures Sepsis was defined using Sepsis-3 clinical consensus criteria. Model discrimination was assessed using area under the receiver operating characteristic curve (AUROC) at the encounter level and prediction level with 4-hour, 12-hour, and hospitalization-wide time horizons. Performance against clinician recognition of sepsis was measured using antibiotics, lactate, and body culture orders.

Results

Of 227 091 inpatient encounters, 7401 (3.3%; median [IQR] age, 65 [54-75] years; 3359 [45.4%] female; 2.7% Asian; 24.6% Black; 64.6% White; 7.1% Hispanic ethnicity) met sepsis criteria and 219 690 (96.7%; median [IQR] age, 48 [33-65] years; 123 563 [56.2%] female; 2.5% Asian; 38.8% Black; 49.6% White; 9.6% Hispanic ethnicity) did not. At the encounter level, the AUROC ranged from 0.82 (95% CI, 0.81-0.83) to 0.92 (95% CI, 0.92-0.93) across study sites. At the prediction level with a 12-hour time horizon, the AUROC ranged from 0.75 (95% CI, 0.74-0.75) to 0.85 (95% CI, 0.85-0.85). Comparison against clinician recognition of sepsis yielded a minor decrease in performance, with the resulting encounter-level AUROC ranging from 0.80 (95% CI, 0.79-0.81) to 0.90 (95% CI, 0.89-0.90) across sites. Positive predictive values remained low, from 0.13 (95% CI, 0.13-0.14) to 0.26 (95% CI, 0.25-0.27), with a high number needed to evaluate and high alert burden. Conclusions and Relevance In this prognostic study of a new sepsis prediction model, a multicenter prospective validation performed across 4 major US health systems found improved discrimination for the early prediction of sepsis but noted high institutional variability, low positive predictive value, and high alert burden.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Prediction AlgorithmsSepsisAgedFemaleHumansMaleMiddle AgedPrognosisProspective StudiesROC CurveUnited States

Autor:innen und Institutionen

  • University of Michigan Medical School, Ann Arbor.
  • Case Western Reserve University School of Medicine, Cleveland, Ohio.
  • Center for Clinical Informatics Research and Education, MetroHealth, Cleveland, Ohio.
  • Department of Biomedical Informatics, Emory University School of Medicine, Atlanta, Georgia.
  • Division of Pulmonary, Allergy, and Critical Care Medicine, Oregon Health & Science University, Portland.
  • Joan and Irwin Jacobs Center for Health Innovation, UC San Diego Health, San Diego, California.

Förderung

  • NCI NIH HHS
  • NHLBI NIH HHS

Zitieren

APA

Wong, A., Currey, D., Schwinne, M., Park-Egan, B., Meyer, S., Gutting, A., Cao, J., Khan, S., Dantes, R., Pan, T., Buchman, T., Singh, K., Bhavani, S. V., Lyons, P. G., Sjoding, M. W., & Tarabichi, Y. (2026). Multicenter Prospective Validation of an Updated Proprietary Sepsis Prediction Model. JAMA Network Open, 9(2), e260181. https://doi.org/10.1001/jamanetworkopen.2026.0181

Vancouver

Wong A, Currey D, Schwinne M, Park-Egan B, Meyer S, Gutting A, et al. Multicenter Prospective Validation of an Updated Proprietary Sepsis Prediction Model. JAMA Network Open. 2026;9(2):e260181. doi:10.1001/jamanetworkopen.2026.0181

BibTeX
@article{Wong2026,
  author = {Wong, Andrew and Currey, Danielle and Schwinne, Megan and Park-Egan, Brenna and Meyer, Sean and Gutting, Andrew and Cao, Jie and Khan, Sharaf and Dantes, Raymund and Pan, Tony and Buchman, Timothy and Singh, Karandeep and Bhavani, Sivasubramanium V and Lyons, Patrick G and Sjoding, Michael W and Tarabichi, Yasir},
  title = {Multicenter Prospective Validation of an Updated Proprietary Sepsis Prediction Model},
  journal = {JAMA Network Open},
  year = {2026},
  volume = {9},
  number = {2},
  pages = {e260181},
  doi = {10.1001/jamanetworkopen.2026.0181}
}
Kostenlos starten →