Air Purifier Intervention for Respiratory Viral Exposure in Elementary Schools

Ye Sun, Dastan Haghnazari, Ching-Ying Huang, Aribah Baig, Minsik Kim, Amparito Cunningham, Colin Skeen, Jack M Wolfson, Stephen T Ferguson, Erica D Pratt, Linda Valeri, Sophia Zhao und 5 weitere

JAMA Network Open · 2025

DOI: 10.1001/jamanetworkopen.2025.36951 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift JAMA Network Open, 2025. Verfasst von Ye Sun und 16 weiteren Autor:innen. Beteiligte Einrichtung: Division of Pulmonary Medicine, Boston Children's Hospital, Boston, Massachusetts. Hauptthemen laut MEDLINE: Schools, Air Filters, Respiratory Tract Infections, Air Pollution, Indoor. Die Arbeit wurde bisher 10-mal zitiert (Crossref) und nennt 34 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NIAID NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance The magnitude of school respiratory virus exposure and the effectiveness of environmental mitigation measures remain unclear.

Objective

To evaluate whether portable high-efficiency particulate air (HEPA) purifiers are associated with reduced respiratory virus exposure in elementary school classrooms. Design, Setting, and Participants This ad hoc secondary analysis was performed between July 2023 and September 2024 and used data from a cluster-randomized, placebo-controlled trial (School Inner-City Asthma Intervention Study) of HEPA purifiers conducted from September 2015 to June 2020. A total of 200 classrooms from 39 public schools in Northeastern US were enrolled and randomized.

Interventions

Classrooms were randomized 1:1 to receive either active HEPA purifiers or visually identical sham HEPA units (4 per classroom). School staff and investigators were blinded to intervention assignments. Main Outcomes and Measures The primary outcome was high viral exposure, identified by K-means clustering of individual viral concentrations. Secondary outcomes included viral diversity (defined as number of detected virus types) and individual viral concentrations. Week-long bioaerosol samples were collected 3 times during 1 school year, and concentrations of 19 respiratory viruses were quantified by digital droplet polymerase chain reaction.

Results

Of the 200 enrolled classrooms (91 in the sham purifier group and 109 in the HEPA purifier group) analyzed, the median (IQR) class size was 19 (18-20) and the median (IQR) grade was 3 (2-5). A total of 532 bioaerosol samples were collected; viruses were detected in 524 samples (98.5%), with a median (IQR) of 3 (2-5) viruses per classroom. Rhinovirus was most prevalent (476 [89.5%]), while respiratory syncytial virus A and B (66 [12.4%] and 127 [23.9%]) as well as influenza A and B (94 [17.7%] and 76 [14.3%]) were also detected. High viral exposure was present in 118 samples (22.2%). The HEPA purifier intervention was not associated with lower odds of high viral exposure (odds ratio [OR], 0.50; 95% CI, 0.08-3.25; P = .46) but did correspond to a modest reduction in viral diversity (β = −1.02; 95% CI, –1.68 to −0.35; P = .003). Elastic net regression identified relative humidity, grade, winter season, and coarse particulate matter as the environmental risk factors for viral exposure. Conclusions and Relevance In this secondary analysis, HEPA purifiers were not associated with a reduction in high viral exposure but were associated with a modest decrease in viral diversity. Multicomponent interventions may be needed to mitigate respiratory viral exposures in schools.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

SchoolsAir FiltersRespiratory Tract InfectionsAir Pollution, IndoorHumansChildFemaleMale

Autor:innen und Institutionen

  • Division of Pulmonary Medicine, Boston Children's Hospital, Boston, Massachusetts.
  • Division of Pulmonary and Critical Care, Massachusetts General Hospital, Boston.
  • Department of Biological Engineering, Inha University, Incheon, Republic of Korea.
  • Division of Allergy and Immunology, Boston Children's Hospital, Boston, Massachusetts.
  • Department of Biomedical Engineering, Boston University, Boston, Massachusetts.
  • Department of Environmental Health, Harvard T.H. Chan School of Public Health, Boston, Massachusetts.

Förderung

  • NIAID NIH HHS

Zitieren

APA

Sun, Y., Haghnazari, D., Huang, C. Y., Baig, A., Kim, M., Cunningham, A., Skeen, C., Wolfson, J. M., Ferguson, S. T., Pratt, E. D., Valeri, L., Zhao, S., Gold, D. R., Balaj, L., Koutrakis, P., Phipatanakul, W., & Lai, P. S. (2025). Air Purifier Intervention for Respiratory Viral Exposure in Elementary Schools. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2025.36951

Vancouver

Sun Y, Haghnazari D, Huang CY, Baig A, Kim M, Cunningham A, et al. Air Purifier Intervention for Respiratory Viral Exposure in Elementary Schools. JAMA Network Open. 2025. doi:10.1001/jamanetworkopen.2025.36951

BibTeX
@article{Sun2025,
  author = {Sun, Ye and Haghnazari, Dastan and Huang, Ching-Ying and Baig, Aribah and Kim, Minsik and Cunningham, Amparito and Skeen, Colin and Wolfson, Jack M and Ferguson, Stephen T and Pratt, Erica D and Valeri, Linda and Zhao, Sophia and Gold, Diane R and Balaj, Leonora and Koutrakis, Petros and Phipatanakul, Wanda and Lai, Peggy S},
  title = {Air Purifier Intervention for Respiratory Viral Exposure in Elementary Schools},
  journal = {JAMA Network Open},
  year = {2025},
  doi = {10.1001/jamanetworkopen.2025.36951}
}
Kostenlos starten →