EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudiePragmatische StudieOpen Access

Advanced Airway Devices and End-Tidal Capnography Trends in Cardiac Arrest

Michelle M J Nassal, Andoni Elola, Elisabete Aramendi, Christopher B Gage, Jonathan R Powell, Xabier Jaureguibeitia, Ahamed H Idris, Mohamud R Daya, Tom P Aufderheide, Jestin Carlson, Shannon W Stephens, Graham Nichol und 3 weitere

JAMA Network Open · 2025

DOI: 10.1001/jamanetworkopen.2025.31511 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift JAMA Network Open, 2025. Verfasst von Michelle M J Nassal und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, The Ohio State University, Columbus. Hauptthemen laut MEDLINE: Capnography, Out-of-Hospital Cardiac Arrest, Airway Management, Intubation, Intratracheal. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 29 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar. Gefördert von: NHLBI NIH HHS.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Importance While variable advanced airway devices are used in out-of-hospital cardiac arrest (OHCA) resuscitation, potential differences in ventilation metrics are not well known.

Objective

To characterize differences in end-tidal carbon dioxide (EtCO 2 ) capnography trajectories between laryngeal tube (LT) and endotracheal intubation (ETI) during OHCA. Design, Setting, and Participants This secondary analysis of EtCO 2 capnography waveforms from the Pragmatic Airway Resuscitation Trial (PART), a multicenter cluster-crossover randomized clinical trial, was performed November 1, 2023, through July 8, 2025. Participants in this analysis were adults (aged ≥18 years) with nontraumatic OHCA from 27 emergency medical services (EMS) agencies, which were placed into 13 clusters. Participants were assigned to LT or ETI airway management. All cases with 50% or greater interpretable EtCO 2 signal were included.

Interventions

LT vs ETI airway management. Main Outcomes and Measures Mean maximal EtCO 2 values within 1-minute epochs and trends over resuscitation after LT or ETI. Associations with OHCA outcomes were also evaluated, including sustained return of spontaneous circulation (ROSC) and 72-hour survival. Using the Mann-Whitney test, EtCO 2 of LT and ETI cases were compared at 20-, 10-, and 1-minute resuscitation. EtCO 2 trends over time were evaluated using Cochran-Armitage test of trend. Covariates in multivariable logistic regression models for outcomes were adjusted, including interaction between advanced airway device and EtCO 2 trends.

Results

Of the 3004 cases in PART, 1113 (818 in LT and 295 in ETI groups) had available EtCO 2 data and were included in the secondary analysis. Patients were mostly male (694 [62.4%]), had a median (IQR) age of 64 (52-75) years, and had a nonshockable (941 [84.6%]), nonpublic (999 [89.8%]) OHCA. ROSC occurred in 144 patients (17.6%) receiving LT and 54 (18.3%) receiving ETI. EtCO 2 values did not differ between LT and ETI groups (20-minute resuscitation: 33.9 vs 29.4 mm Hg, P = .07; 10-minute resuscitation: 30.9 vs 28.5 mm Hg, P = .89; 1-minute resuscitation: 32.2 vs 28.3 mm Hg, P = .28). In ROSC compared with non-ROSC cases, patients in LT (27.9 to 52.3 mm Hg vs 32.6 to 23.5 mm Hg; P < .001) and ETI (38.2 to 46.7 mm Hg vs 27.7 to 20.0 mm Hg; P < .001) groups exhibited increasing EtCO 2 during resuscitation. EtCO 2 trend and advanced airway interaction was associated with ROSC (odds ratio [OR], 1.75; 95% CI, 1.25-2.45) but not survival (OR, 1.21; 95% CI, 0.90-1.61). Therefore, we performed an advanced airway stratified analysis for ROSC (ETI: OR, 2.34 [95% CI, 1.67-3.26]; LT: OR, 1.33 [95% CI, 1.20-1.47]). Conclusions and Relevance In this secondary analysis of PART, EtCO 2 values did not differ between LT and ETI. However, due to significant interaction between advanced airway device and EtCO 2 trends, individual interpretation of these parameters may not be accurate.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

CapnographyOut-of-Hospital Cardiac ArrestAirway ManagementIntubation, IntratrachealCardiopulmonary ResuscitationHumansMaleFemaleMiddle AgedAgedCross-Over StudiesCarbon Dioxide

Substanzen

Carbon Dioxide

Autor:innen und Institutionen

  • Department of Emergency Medicine, The Ohio State University, Columbus.
  • Department of Electronic Technology, BioRes Group, University of the Basque Country, Universidad del País Vasco/Euskal Herriko Unibertsitatea (UPV/EHU), Bilbao, Spain.
  • Department of Communication Engineering, BioRes Group, University of the Basque Country, UPV/EHU, Bilbao, Spain.
  • National Registry of Emergency Medical Technicians, Columbus, Ohio.
  • ImageTrend, LLC, Eagan, Minnesota.
  • Department of Emergency Medicine, University of Texas Southwestern Medical Center, Dallas.

Förderung

  • NHLBI NIH HHS

Zitieren

APA

Nassal, M. M. J., Elola, A., Aramendi, E., Gage, C. B., Powell, J. R., Jaureguibeitia, X., Idris, A. H., Daya, M. R., Aufderheide, T. P., Carlson, J., Stephens, S. W., Nichol, G., Schmicker, R. H., Panchal, A. R., & Wang, H. E. (2025). Advanced Airway Devices and End-Tidal Capnography Trends in Cardiac Arrest. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2025.31511

Vancouver

Nassal MMJ, Elola A, Aramendi E, Gage CB, Powell JR, Jaureguibeitia X, et al. Advanced Airway Devices and End-Tidal Capnography Trends in Cardiac Arrest. JAMA Network Open. 2025. doi:10.1001/jamanetworkopen.2025.31511

BibTeX
@article{Nassal2025,
  author = {Nassal, Michelle M J and Elola, Andoni and Aramendi, Elisabete and Gage, Christopher B and Powell, Jonathan R and Jaureguibeitia, Xabier and Idris, Ahamed H and Daya, Mohamud R and Aufderheide, Tom P and Carlson, Jestin and Stephens, Shannon W and Nichol, Graham and Schmicker, Robert H and Panchal, Ashish R and Wang, Henry E},
  title = {Advanced Airway Devices and End-Tidal Capnography Trends in Cardiac Arrest},
  journal = {JAMA Network Open},
  year = {2025},
  doi = {10.1001/jamanetworkopen.2025.31511}
}
Kostenlos starten →