Accuracy of Diagnosing Heparin-Induced Thrombocytopenia
JAMA Network Open · 2024
DOI: 10.1001/jamanetworkopen.2024.3786 ↗Kurz gefasst
Fachartikel in der Zeitschrift JAMA Network Open, 2024. Verfasst von Emil List Larsen und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Clinical Biochemistry, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark. Hauptthemen laut MEDLINE: Thrombocytopenia. Die Arbeit wurde bisher 12-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei in PubMed Central verfügbar.
Abstract (Originalsprache)
Importance Heparin-induced thrombocytopenia (HIT) is a life-threatening condition that requires urgent diagnostic clarification. However, knowledge of the diagnostic utility of the recommended diagnostic tests is limited in clinical practice.
Objective
To evaluate the current diagnostic practice for managing the suspicion of HIT. Design, Setting, and Participants This prospective diagnostic study was conducted from January 2018 to May 2021 among consecutive patients with suspected HIT from 11 study centers in Switzerland, Germany, and the United States. Detailed clinical data and laboratory information were recorded. Platelet factor 4/heparin antibodies were quantified using an automated chemiluminescent immunoassay (CLIA). A washed-platelet heparin-induced platelet activation (HIPA) test was used as a reference standard to define HIT. Exposures Suspicion of HIT. Main Outcomes and Measures The primary outcome was the diagnostic accuracy of the 4Ts score, the CLIA, and the recommended algorithm serially combining both tests.
Results
Of 1448 patients included between 2018 and 2021, 1318 were available for the current analysis (median [IQR] age, 67 [57-75] years; 849 [64.6%] male). HIPA was positive in 111 patients (prevalence, 8.4%). The most frequent setting was intensive care unit (487 [37.0%]) or cardiovascular surgery (434 [33.0%]). The 4Ts score was low risk in 625 patients (46.8%). By 2 × 2 table, the numbers of patients with false-negative results were 10 (9.0%; 4Ts score), 5 (4.5%; CLIA), and 15 (13.5%; recommended diagnostic algorithm). The numbers of patients with false-positive results were 592 (49.0%; 4Ts score), 73 (6.0%; CLIA), and 50 (4.1%; recommended diagnostic algorithm), respectively. Conclusions and Relevance In this diagnostic study of patients suspected of having HIT, when the recommended diagnostic algorithm was used in clinical practice, antibody testing was required in half the patients. A substantial number of patients were, however, still misclassified, which could lead to delayed diagnosis or overtreatment. Development of improved diagnostic algorithms for HIT diagnosis should be pursued.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Substanzen
Autor:innen und Institutionen
- Department of Clinical Biochemistry, Copenhagen University Hospital-Rigshospitalet, Copenhagen, Denmark.
- Department of Clinical Chemistry, Inselspital, Bern University Hospital, Bern, Switzerland.
- Graduate School for Health Sciences, University of Bern, Bern, Switzerland.
- Division of Medical Oncology and Hematology, University Hospital Zurich, Zurich, Switzerland.
- Diagnostic Haematology, Basel University Hospital, Basel, Switzerland.
- Department of Transfusion Medicine, Institute of Transfusion Medicine, University Medicine Greifswald, Greifswald, Germany.
Zitieren
APA
Larsen, E. L., Nilius, H., Studt, J. D., Tsakiris, D. A., Greinacher, A., Mendez, A., Schmidt, A., Wuillemin, W. A., Gerber, B., Vishnu, P., Graf, L., Kremer Hovinga, J. A., Goetze, J. P., Bakchoul, T., & Nagler, M. (2024). Accuracy of Diagnosing Heparin-Induced Thrombocytopenia. JAMA Network Open. https://doi.org/10.1001/jamanetworkopen.2024.3786
Vancouver
Larsen EL, Nilius H, Studt JD, Tsakiris DA, Greinacher A, Mendez A, et al. Accuracy of Diagnosing Heparin-Induced Thrombocytopenia. JAMA Network Open. 2024. doi:10.1001/jamanetworkopen.2024.3786
BibTeX
@article{Larsen2024,
author = {Larsen, Emil List and Nilius, Henning and Studt, Jan-Dirk and Tsakiris, Dimitrios A and Greinacher, Andreas and Mendez, Adriana and Schmidt, Adrian and Wuillemin, Walter A and Gerber, Bernhard and Vishnu, Prakash and Graf, Lukas and Kremer Hovinga, Johanna A and Goetze, Jens P and Bakchoul, Tamam and Nagler, Michael},
title = {Accuracy of Diagnosing Heparin-Induced Thrombocytopenia},
journal = {JAMA Network Open},
year = {2024},
doi = {10.1001/jamanetworkopen.2024.3786}
}
EUVIMED