Medical Imaging and Pediatric and Adolescent Brain Tumor Risk
JAMA · 19.11.2026
DOI: 10.1001/jama.2026.20441 ↗Kurz gefasst
Fachartikel in der Zeitschrift JAMA, online erschienen am 19.11.2026. Verfasst von Diana L. Miglioretti und 15 weiteren Autor:innen. Die Arbeit nennt 54 Literaturangaben.
Abstract (Originalsprache)
Importance Ionizing radiation from medical imaging may increase brain tumor risk.
Objective
To quantify brain tumor risk associated with radiation exposure from medical imaging in children and adolescents. Design, Setting, and Participants Retrospective cohort study of children born from 1996 through 2016 who were enrolled from birth in 6 US health care systems or Ontario, Canada, and were alive and cancer-free at age 2 years, with follow-up through December 31, 2017 (US sites), and December 31, 2024 (Ontario). Exposures Cumulative radiation dose to the brain from medical imaging, lagged by 2 years. Main Outcomes and Measures Incident brain or other central nervous system tumors. Hazard ratios (HRs) were estimated using Cox proportional hazards models for categorical dose, and excess relative risks (ERRs) were estimated using linear dose-response models for continuous dose.
Results
Among 3 704 860 children (1 900 285 [51.3%] male) followed up for 45 671 641 person-years (mean follow-up, 12.3 years), 1536 brain tumors were diagnosed. Mean radiation dose from 1 head computed tomography (CT) examination was 66.2 mGy (SD, 22.2). Among children with cumulative dose of 1 mGy or greater, mean cumulative dose was 73 mGy (SD, 95) overall and 100 mGy (SD, 105) among those diagnosed with brain tumors. Compared with no exposure, brain tumor risk increased with cumulative dose (>0 to <1 mGy: HR, 1.12 [95% CI, 1.01-1.26]; 1 to <5 mGy: HR, 1.71 [95% CI, 0.88-2.96]; 5 to <50 mGy: HR, 1.86 [95% CI, 1.16-2.81]; 50 to <75 mGy: HR, 2.30 [95% CI, 1.64-3.12]; 75 to <100 mGy: HR, 2.02 [95% CI, 1.13-3.30]; 100 to <150 mGy: HR, 2.81 [95% CI, 1.53-4.66]; ≥150 mGy: HR, 3.85 [95% CI, 2.43-5.75]). Cumulative dose was associated with brain tumor risk overall (ERR per 100 mGy, 1.27 [95% CI, 0.83-1.77]; P < .001), with stronger associations for aggressive histologies (ERR per 100 mGy, 1.51 [95% CI, 1.00-2.11]; P < .001). By age 21 years, exposure comparable to 1 head CT was associated with 7.9 excess brain tumors per 10 000 children, or approximately 1 excess tumor per 1266 head CT examinations. The estimated population-attributable fraction was 10.1% (95% CI, 5.8%-14.2%). Conclusions and Relevance Medical imaging in children and adolescents was associated with a dose-related increase in brain tumor risk. These findings support careful clinical justification and dose minimization when pediatric imaging using ionizing radiation is indicated.
Zitieren
APA
Miglioretti, D. L., Alber, S. A., Kwan, M. L., Pequeno, P., Bowles, E. J. A., Greenlee, R. T., Stout, N. K., Weinmann, S., Mahendra, M., Francisco, M., Moy, L. M., Stewart, C., Bolch, W. E., Duncan, J. R., Pole, J. D., & Smith-Bindman, R. (2026). Medical Imaging and Pediatric and Adolescent Brain Tumor Risk. JAMA. https://doi.org/10.1001/jama.2026.20441
Vancouver
Miglioretti DL, Alber SA, Kwan ML, Pequeno P, Bowles EJA, Greenlee RT, et al. Medical Imaging and Pediatric and Adolescent Brain Tumor Risk. JAMA. 2026. doi:10.1001/jama.2026.20441
BibTeX
@article{Miglioretti2026,
author = {Miglioretti, Diana L. and Alber, Susan A. and Kwan, Marilyn L. and Pequeno, Priscila and Bowles, Erin J. A. and Greenlee, Robert T. and Stout, Natasha K. and Weinmann, Sheila and Mahendra, Malini and Francisco, Melanie and Moy, Lisa M. and Stewart, Carly and Bolch, Wesley E. and Duncan, James R. and Pole, Jason D. and Smith-Bindman, Rebecca},
title = {Medical Imaging and Pediatric and Adolescent Brain Tumor Risk},
journal = {JAMA},
year = {2026},
doi = {10.1001/jama.2026.20441}
}
EUVIMED